x

Bridgent Seismic Protection & Structural Safety

Home / Solutions / Build / Seismic Protection
Build

Seismic Protection

A pioneer in earthquake-resistant engineering, Bridgent delivers a comprehensive portfolio of seismic protection devices and integrated services under our trusted product range — engineered to safeguard structures across the full seismic spectrum.

Applications
Bridges Stadiums Water Infrastructures Energy Infrastructures Viaducts
Benefits

Why choose Bridgent seismic systems

01.

Wide Range of Applications

New construction, retrofitting of existing structures, and post-earthquake rehabilitation. Bridges, viaducts, industrial facilities, energy plants, heritage buildings, hospitals, and schools.

02.

Wide Range of Solutions

Built on four core principles — Isolation, Energy Dissipation, Connection, and Junction — used individually or in combination to address any seismic scenario.

03.

Cost Savings

Average upfront savings of 15% on total project cost. Structures remain operational after seismic events, significantly reducing post-earthquake rebuilding expenditure.

04.

Environment-Friendly

Seismic protection devices substantially reduce the mass of superstructures and foundations, lowering material consumption and the overall environmental footprint.

05.

Low Maintenance

Designed for straightforward installation and replacement, our seismic devices require minimal ongoing maintenance throughout their service life.

06.

Approved Systems

Full compliance with all applicable international standards. CE marking available on request, ensuring regulatory acceptance across global markets.

07.

Tailored Solutions

Beyond off-the-shelf products, we engineer bespoke solutions calibrated to the specific seismic hazard, structural characteristics, site conditions, and budget constraints.

08.

Full Service

End-to-end capability — from seismic risk analysis and structural assessment through device design, manufacturing, installation, and long-term maintenance.

Bridgent Seismic Devices at a Glance

Bridgent Seismic Protection Solutions — full product range including HDRB, LRB, PS, FD, PDS, STU and SFX devices

Four Protective Concepts

  • Isolation — Rubber isolators (HDRB, LRB, LDRB) and Pendulum systems (PS)
  • Dissipation — Hydraulic products: Fluid Damper (FD) and Prestressing Damping Spring (PDS)
  • Connection — Hydraulic Shock Transmission Unit (STU)
  • Junction — Supported mat joint (SFX) for structural movement absorption

Each device category can be deployed independently or in synergistic combination, allowing engineers to optimise seismic performance across a wide range of structural typologies and hazard levels.

Bridgent seismic engineering — structural analysis and device design using advanced simulation software

Structural Analysis Meets Device Engineering

Our specialist technical teams provide dual expertise at the earliest project stages, combining structural seismic analysis with deep knowledge of protection device behaviour.

Our engineers will assist you to:

  • Evaluate the seismic response characteristics of your structure
  • Identify and specify the most appropriate protection strategy

We place this integrated expertise at the disposal of structural designers and project owners, delivering practical, cost-optimised solutions that minimise seismic risk throughout the infrastructure lifecycle.

From risk assessment to
installation...
and maintenance

Seismic risk assessment and structural design — Bridgent engineering team

Risk Assessment, Evaluation of Protection Options and Design

  • Evaluation of structural seismic behaviour using linear spectral analysis and non-linear time-history methods
  • Definition of the required seismic performance targets
  • Engineering of the device configuration to meet those specifications

Prototypes are produced in-house and subjected to rigorous testing at our dedicated laboratory facility to validate the final design before production.

Guarantee of Product Performance and Quality

The entire supply chain and manufacturing process conforms to CE marking requirements. Production testing is conducted routinely to ensure reproducible, certified performance. For CE marking compliance, a minimum of 20% of production output is tested in our state-of-the-art laboratory — the most comprehensively equipped facility of its kind.

Seismic device manufacturing and quality testing — Bridgent production facility
On-site seismic device installation — Bridgent technical team

Technical Support or Full Installation

Bridgent provides on-site technical supervision to guide clients through device installation in strict accordance with engineering specifications and best practice. On request, our project teams can assume full responsibility for the complete installation scope, including all associated civil and structural works.

Photo credit: ITER Organization

Inspection and Maintenance

In the aftermath of a seismic event, Bridgent's qualified technicians and structural engineers conduct thorough inspections of installed seismic devices to assess their condition, evaluate repair requirements, and recommend appropriate structural repair or strengthening interventions to restore full protection capacity.

Post-earthquake inspection and maintenance of seismic isolation bearings — Bridgent engineers

Seismic Protection Devices

Damping systems   Damping systems   Damping systems   Damping systems   Damping systems  

Bridgent® Damping Systems

Bridgent damping systems dissipate seismic energy to minimise structural impact. Highly effective under rapid dynamic loading — earthquakes, vessel impacts — while offering negligible resistance to slow service movements. Compatible with isolation systems including High Damping Rubber Bearings.

Learn More
Isolation systems   Isolation systems   Isolation systems   Isolation systems   Isolation systems  

Bridgent® Isolation Systems

Bridgent isolation systems extend the fundamental vibration period of the protected structure, reducing seismic acceleration response by a factor of two to three — substantially lowering forces transmitted to structural elements.

Learn More
Connection system   Connection system   Connection system   Connection system   Connection system  

Bridgent® Connection System

The Bridgent Shock Transmission Unit (STU) rigidly links structural elements during seismic events, emergency braking, or extreme wind loading, while permitting free thermal movement under normal service conditions.

Learn More
Junction system   Junction system   Junction system   Junction system   Junction system  

Bridgent® Junction System

The Bridgent SFX supported mat joint accommodates structural movements imposed by the main structure through controlled deformation of its elastomeric sections, providing reliable seismic joint performance.

Learn More
Seismic retrofitting   Seismic retrofitting   Seismic retrofitting   Seismic retrofitting   Seismic retrofitting  

Seismic Retrofitting

From developing a comprehensive seismic protection strategy to supplying and installing systems designed, manufactured, and tested in-house, Bridgent delivers turnkey solutions for retrofit, seismic strengthening, and post-earthquake repair of existing structures.

Learn More

Download Bridgent
Seismic Brochure

Documentation

Find Out More in Our Case Studies

Contact Us

Have a question about our bearing solutions, or ready to discuss a specific project? Complete the form below and a Bridgent specialist will respond promptly.

* Mandatory fields

+86 15116183980

+86 15116183980

lkvicky2003@gmail.com

+